• Patients
    • What is FES
    • Who it can help
    • Treatment Options
    • Referral Options
    • Treatment pathway – UK
    • Clinics
    • PD Warrior Classes
    • Research/Evidence
    • Testimonials
    • NHS Funding
    • Information Pack
    • FAQ
  • Healthcare Professionals
    • What is FES
    • Who it can help
    • Treatment Options
    • Referral options
    • Training courses
    • FES Clinician Forum
    • Forms
    • Treatment pathway – UK
    • Research/Evidence
    • Knowledge Base
    • NHS Funding
    • Become a FES Practitioner
    • Information Pack
    • FAQ
  • Products
    • Stimulators
    • Electrodes
    • Electrode leads
    • Footswitches
    • Footswitch leads
    • Insoles
    • Accessories
    • Batteries
    • Constraint Mitten (CMIT)
  • Support for Patients
  • Contact

!Please Note: We are looking for independent clinicians accessible to Norwich

Email us
+
!
  • About
  • Community
  • Patients
    • What is FES
    • Who it can help
    • Treatment Options
    • Referral Options
    • Treatment pathway – UK
    • Clinics
    • PD Warrior Classes
    • Research/Evidence
    • Testimonials
    • NHS Funding
    • Information Pack
    • FAQ
  • Healthcare Professionals
    • What is FES
    • Who it can help
    • Treatment Options
    • Referral options
    • Training courses
    • FES Clinician Forum
    • Forms
    • Treatment pathway – UK
    • Research/Evidence
    • Knowledge Base
    • NHS Funding
    • Become a FES Practitioner
    • Information Pack
    • FAQ
  • Products
    • Stimulators
    • Electrodes
    • Electrode leads
    • Footswitches
    • Footswitch leads
    • Insoles
    • Accessories
    • Batteries
    • Constraint Mitten (CMIT)
  • Support for Patients
  • Contact

Home > Products > Stimulators > Microstim 2V2

Stimulator | SKU: 00-001-0002

Microstim 2V2

The MICROSTIM2v2 neuromuscular stimulator is intended for the exercise of weak or paralysed muscle. It is designed to be simple to use with the minimum necessary user controls. The output stimulation intensity is ramped at the beginning and end of each cycle by pulse width modulation to produce a comfortable sensation. This makes it particularly appropriate for patients who may have elevated muscle tone due to spasticity.

Read More +
Request Product

Details

The Microstim 2v2 can be used for muscle training a re-education of movement. Modes can be chosen for reciprocal muscle pairs and muscles pairs that act synergistically.

There is also specific modes for the treatment of shoulder subluxation where the output from the two channels overlaps.

The first channel (anterior and posterior deltoid) will lift the humorous in to the glenoid-humerus socket while the 2nd channel (middle deltoid and supraspinatus) is used to maintain the position while the first set of muscles are rested.

The device is also used for abdominal muscle stimulation for the control of constipation for people with neuropathic bowel and IBS-C.

Clinician manuals are available by emailing sales@odstockmedical.com

Microstim2 Manual_POML052-MS2v2_Doc V16.00

SKU: 00-001-0002



Technical spec table

Mode Frequency Format Application
0 40 Hz ALTERNATE Slow ramp (6s) 8s on 8s off • A slow ramp is used when there is a high level of spasticity • Reciprocal muscle pairs
1 40 Hz SIMULTANEOUS Slow ramp (6s) 8s on 8s off • A slow ramp is used when there is a high level of spasticity • Synergistic muscle pairs
2 20 Hz CONTINUOUS • Setting up electrode positions and stimulation levels
3 20 Hz ALTERNATE Standard ramp (2s) 8s 0n 8s off • Lower frequency to avoid muscle fatigue • Reciprocal muscle pairs
4 20 Hz SIMULTANEOUS Standard ramp (2s) 8s on 2 s off • Lower frequency to avoid muscle fatigue • Synergistic muscle pairs
5 40 Hz CONTINUOUS • Setting up electrode positions and stimulation levels or when using a stimulation probe
6 40 Hz ALTERNATE Standard ramp (2s) 8s 0n 8 s off • Higher frequency for general muscle training • Reciprocal muscle pairs
7 40 Hz SIMULTANEOUS Standard ramp (2s) 8s on 2s off • Higher frequency for general muscle training • Synergistic muscle pairs
8 40 Hz OVERLAPPING Standard ramp (2s) 10s on 6s off • Shoulder subluxation
9 20 Hz OVERLAPPING Standard ramp (2s) 10s on 6s off • Shoulder subluxation – lower frequency to reduced muscle fatigue

How to Order

If you wish to place an order, please fill out the order form below. If you require further assistance call customer services on 01722 439540 or email sales@odstockmedical.com.

"*" indicates required fields

* = required field

"*" indicates required fields

Please note this form is to request previous versions of our stimulator/OML LINQ™/Remote manuals or for an alternative language. If you require the current patient stimulator/OML LINQ™/Remote manual please click on the details tab and scroll down. If you require a clinician version of a stimulator manual please email sales@odstockmedical.com. There are no clinician manuals for OML LINQ™ or OML Remote. Thank you

Posted or digital format*
Address
Opt in to receive emails and letters from Odstock Medical Limited about

Our Opening Hours

Mon - Fri: 9am - 5pm

Sat - Sun: Closed

  • +44 (0)1722 439 540
  • enquiries@odstockmedical.com

Related Products

Looking for something else?

ODFS® Pace

Find out more

Microstim2v2 Orthopaedic Stimulator “Orthostim”

Find out more

Odstock 2-Channel Stimulator

Find out more

Have a question?

+44 (0)1722 439 540
enquiries@odstockmedical.com
  • Odstock Medical Ltd.
    The National Clinical FES Centre
    Salisbury District Hospital
    Salisbury, Wiltshire SP2 8BJ
  • +44 (0)1722 439 540
  • enquiries@odstockmedical.com
  • Twitter Icon

Our Opening Hours

Mon - Fri: 9am - 5pm Sat - Sun: Closed

Newsletter Signup

For Healthcare professionals to stay in the know with what Odstock Medical Ltd is doing!

Signup Today

About Odstock Medical Ltd

  • Who we help
  • How we help
  • History
  • Meet the team
  • Job opportunities
  • Contact

Help & Information

  • Patients
  • Healthcare Professionals
  • FES Products
  • Knowledge Base
  • International
  • Community
  • Accessibility

© 2025 Odstock Medical|Website by blue bee

  • Terms of use
  • Privacy Notice
  • Conflict Minerals Statement
  • Modern Slavery Statement
  • Carbon Reduction Plan 2024
  • Safeguarding Policy

Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}